ESXi ISO, based on the standard VMware, is the easiest and most reliable way to install ESXi on HPE ProLiant servers. It includes all of the required drivers and management software to run ESXi on HPE ProLiant servers, and works seamlessly with Intelligent Provisioning.

Summary When I try to install ESXi 5.5U3 on a DL360 G6, it fails because no storage is seen. Hp Officejet 6110xi Drivers For Windows 7. Details Hardware Server: HP Proliant DL360 G6 CPUs: 1 CPU, Intel Xeon E5506 @ 2.13GHz RAM: 48GB RAM Storage Adapter: P410i Storage: 2x 1TB HP SATA drives Storage config: RAID '10' on two drives, single 1TB 'Logical Volume' Install Process ESXi compatibility for DL360 G6: ESXi source: HPE custom ESXi 5.5 U3 from I'm booting using the ILO virtual media on an HTTP-provided ISO. This process works fine and I've had no issues with it on my local LAN. Here are some details about that generic boot process using the ILO CLI: hpiLO->power power: server power is currently: Off hpiLO->cd /map1/oemhp_vm1/cddr1 hpiLO->set oemhp_image=hpiLO->set oemhp_boot=connect hpiLO->power on After answering the usual VMware prompts, I eventually arrive at this screen and can go no farther: I've tried wiping the RAID logical volume using DBAN, just in case any prior data on there was confusing ESXi, but that changed nothing. Southpaw Grammar Morrissey Rar.

This also shows that the storage hardware works since I was able to see the storage using DBAN just fine. The closest related question I found so far that would be similar to this was this question:. Firebird Php Generator Professional Letter. In that case, the admin wanted a JBOD disk pass-through, which isn't possible on the HP Proliant internal storage P410i controllers. Normally I'd try loading a special HPE storage driver, but those are supposedly included on the HPE custom images. Anyone else running ESXi 5.5U3 on a DL360 G6 see this problem and get past it?

Are there logs available somehow to show what's failing on the storage detection? Thanks in advance for any help! The non-HP VMware image worked great. What the heck? I wasn't expecting that. I grabbed ESXi 5.5.0U3 from (MD5: 279685120bdb867172dc1e0c7e93514e) and the storage configuration screen showed just what I'd expect: I'm not sure what value HP is adding to those VMware images, but for Future Me or anyone else, it's worth trying the non-HP images if things don't seem to work with the HP images.

UPDATE: The HP 5.5 U2 image also works. Even though 5.5 U3 is on the compatibility list for a DL360 G6, it would appear that this release doesn't actually work properly. The 5.5 U2 image name that works is VMware-ESXi-5.5.0-Update2-2403361-HP-550.9.2.40.2-Sep2015 (MD5: 4733f9d0d167).